Kidde i12080 User Manual

Browse online or download User Manual for Safety Kidde i12080. Kidde i12080 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
AC Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization Smoke
Alarm with SMART HUSH
TM
Control to temporarily silence nuisance alarms.
Models i12040 and i12080 have a 9-Volt Battery Back Up and the model i12080
has a battery powered safety light.
Thank you for purchasing this smoke alarm. It is an important part of your family’s
home safety plan. Y
ou can trust this product to provide the highest quality safety pro-
tection. We know you expect nothing less when the lives of your family are at stake.
Kidde alarms and accessories CAN ONLY BE interconnected with other Kidde alarms
and accessories as well as specified brands and models of interconnect compatible
alarms. Connection of Kidde products to a non-specified manufacturer’s interconnect
system, or connection with non-specified equipment from another manufacturer into
an existing Kidde system could result in nuisance alarming, failure to alarm, or dam-
age to one or all of the devices in the interconnect system. Refer to the User’s Guide
supplied with each Kidde product for interconnect compatible models, brands, and
devices. Refer to the wiring instructions in section 3 for NFPA initiating device limits.
For models:
i12020, i12040, i12080
Manual P/N 820-1183 Rev. B 11/2006
i12020
i12040
i12080
For your convenience, write down the following information. If you call
our Consumer Hotline, these are the first questions you will be asked.
Smoke Alarm Model Number
(located on back of alarm):
Date Code (located on back of alarm): The
National Fire Protection Association (NFPA)
and the manufacturer recommend replacing
this alarm ten years from the date code.
Date of Purchase:
Where Purchased:
Smoke Alarm User’s Guide
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - Smoke Alarm User’s Guide

AC Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization SmokeAlarm with SMART HUSHTMControl to temporarily silence nuisance alarms.Mod

Page 2 - CONTENTS OF THIS MANUAL

Hush®mode: The red LED will illuminate for 1.5 seconds every 8 seconds, indicating the smoke alarm is in the Hush®mode.Testing: Test by pushing the T

Page 3 - FIGURE 2 FIGURE 3

6. MAINTENANCEALARM REMOVALIF TAMPER RESIST PIN HAS BEEN USED, REFER TO TAMPER RESIST LOCK-ING PIN IN SECTION 3 FOR PIN REMOVAL INSTRUCTIONS.To replac

Page 4 - 2. LOCATIONS TO AVOID

The SAFETY LIGHT (model i12080 only) portion is powered by one (1) 9V alka-line battery. Under normal (standby) conditions, the battery should last a

Page 5 - WIRING REQUIREMENTS

CAUTION! USE ONLY LAMP SPECIFIED. USE OF A DIFFERENT LAMP MAYHAVE A DETRIMENTAL EFFECT ON THE SMOKE ALARM OR THE SAFETYLIGHT OPERATION.CLEANING YOUR

Page 6 - MOUNTING INSTRUCTIONS

• Smoke alarms must be tested regularly to make sure the batteries and thealarm circuits are in good operating condition.• Smoke alarms cannot provide

Page 7

awakened by the alarm sound, or to those who may be incapable of safelyevacuating the area unassisted.WHAT TO DO WHEN THE ALARM SOUNDS• Alert small ch

Page 8 - 4. OPERATION AND TESTING

Smoke Detection – Where required by applicable laws, codes, or standards forthe specified occupancy, approved single- and multiple-station smoke alarm

Page 9

FIVE YEAR LIMITED WARRANTYKIDDE Safety warrants to the original purchaser that the enclosed smoke alarm (butnot the battery) will be free from defects

Page 10 - 5. NUISANCE ALARMS

This alarm detects products of combustion using the ionization technique. Itcontains 0.9 microcurie of Americium 241, a radioactive material (see sect

Page 11 - 6. MAINTENANCE

FIGURE 1FIGURE 2 FIGURE 3• Locate at least one alarm on every floor level.• Locate an alarm in every bedroom.• Locate an alarm in every room where ele

Page 12

• Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3ft(0.9m) of the highest point (measured horizontally). NFPA 72 states: “S

Page 13 - CLEANING YOUR ALARM

air supply ducts used for heating or cooling, ceiling or whole house ventilatingfans, or other high air flow areas.• Kitchens. Normal cooking may caus

Page 14 - 8. GOOD SAFETY HABITS

• When mixing models which have battery backup (i12040, i12060, i12080,1275, 1276, 1285, 1296, PE120, PI2000, KN-COSM-IB, RF-SM-ACDC,HD135F, KN-COB-IC

Page 15 - 10. NFPA REQUIRED PROTECTION

1. Remove the trim ring from the back of the alarm by holding the trim ring andtwisting the alarm in the direction indicated by the “OFF” arrow on the

Page 16 - 12. SERVICE AND WARRANTY

TAMPER RESIST LOCKING PIN: To make your smoke alarm tamper resistant, alocking pin has been provided with your alarm. Using this pin will help deterc

Page 17 - FIVE YEAR LIMITED WARRANTY

NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEATURE ANDSOUND A CONTINUOUS ALARM.CAUTION: BEFORE USING THE ALARM HUSH FEATURE, IDENTIFY THESOURCE