Tamper Resist Features
This alarm has a tamper resist feature, which helps prevent someone from
removing the unit from the mounting bracket. Activate the smoke alarm tamper
resist feature by breaking off the four posts in the square holes in the mounting
bracket (see Figure 9A). When the posts are broken off, the tamper resist tab on
the base is allowed to engage the mounting bracket. Rotate the alarm onto the
mounting bracket until you hear the tamper resist tab snap into place, locking
the alarm on the mounting bracket. Using the tamper resist feature will help
deter children and others from removing the alarm from the bracket. NOTE: To
remove the alarm when the tamper resist tab is engaged, press down on the
the tamper resist tab, and rotate the alarm off the bracket (see Figure 9B).
4. OPERATION AND TESTING
OPERATION
The smoke alarm is operating once AC power is supplied, a fresh battery is
installed and testing is complete. When the smoke alarm ionization chamber
senses products of combustion, the horn will sound a loud (85db) temporal
alarm until the sensing chamber is cleared of smoke particles.
Smart HUSH
®
CONTROL: The Smart HUSH
®
feature has the capability of tem-
porarily desensitizing the smoke sensing circuitry in order to quiet your alarm
while you take care of a non-emergency event. This feature is to be used only
when a known alarm condition, such as smoke from cooking, activates the
alarm. Activate Smart HUSH
®
control by pushing the button on the smoke alarm
cover. If the smoke is not too dense, the alarm will silence immediately. The
green LED will blink every 2 seconds for approximately 7 minutes to indicate
that the alarm is in a temporarily desensitized condition. The smoke alarm will
automatically reset after approximately 7 minutes, and will sound again if parti-
cles of combustion are still present. The Smart HUSH
®
feature can be used
repeatedly until the air has been cleared of the condition causing the alarm.
Pushing the test button on the alarm will end the HUSH
®
period.
FIGURE 9A FIGURE 9B