Kidde KN-COB-DP-LS User Manual

Browse online or download User Manual for Carbon monoxide (CO) detectors Kidde KN-COB-DP-LS. Kidde KN-COB-DP-LS User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Manual P/N 820-1371 Rev. C 10/12 2526-7206-00
ATTENTION: Please take a few minutes to thoroughly read this user’s
guide which should be saved for future reference and passed on to any
subsequent owner.
Carbon Monoxide Alarm
User’s Guide
Models: KN-COB-DP-LS and KN-COP-DP-LS
KN-COP-DP-LS with Digital Display
• 120V AC Plug-In
• 9V Battery Backup
• Tamper Resist Feature
• Peak Level Memory
KN-COB-DP-LS
• 120V AC Plug-In
• 9V Battery Backup
• Tamper Resist Feature
Carbon Monoxide Alarm
Carbon Monoxide Alarm
2526-7206-00(820-1371 Rev. C).qxd:_ 2012.11.5 2:21 PM
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - User’s Guide

Manual P/N 820-1371 Rev. C 10/12 2526-7206-00ATTENTION: Please take a few minutes to thoroughly read this user’sguide

Page 2 - WARNING:

2. Product Features and Specificationsbattery to be changed without the alarm sounding. To deactivate thefeature, press in the Tamper-Resist Activati

Page 3 - Important Warning Statements

Recommended Installation LocationsCO alarms should be mounted in ornear bedrooms and living areas. It isrecommended that you install a KiddeCO alarm o

Page 4 - Contents of This User’s Guide

When you first power up the alarm: The red Alarm LED will light andthe alarm will sound briefly, then the green Operate LED will light. Thisindicates

Page 5

6. KN-COB-DP-LS Operating CharacteristicsCarbonmonoxidealarmRed LED flashes withbeeps. 4 quick beeps, 5 seconds silence,repeatingAlarm condition.Dang

Page 6

The following table illustrates the possible digital displays, describes theaudible alarm patterns, and the recommended actions to take.Operating and

Page 7

Peak Level MemoryWhen the Peak Level button is pressed and held, the display shows thehighest CO reading taken by the CO alarm since its last Peak Lev

Page 8

Battery ReplacementNOTE: This CO alarm is not battery operated. However, these alarmsare equipped with 9 volt battery backup – the 9 volt battery is t

Page 9

7. Maintenance• Avoid spraying air fresheners, hair spray, paint or other aerosols nearthe alarm. • Do not paint the unit. Paint will seal the vents a

Page 10

TEN YEAR LIMITED WARRANTYWarranty Coverage: The manufacturer warrants to the original consumer purchaser, thatthis product (except battery) will be fr

Page 11 - 3. Installation Locations

Carbon Monoxide Alarm Procedure1) Operate the Test/Reset button;2) Call your emergency services (Fire Department or 911);3) Immediately move to fresh

Page 12 - 5. Alarm Characteristics

WelcomeNote: Many times throughout this User’s Guide, we will refer toCarbon Monoxide as “CO”.This Kidde carbon monoxide (CO) alarm is an important pa

Page 13

Important Warning StatementsWARNING: This product is intended for use in ordinaryindoor locations of family living units. It is not designed to meas-u

Page 14 - Operating Characteristics

1. Information About Carbon MonoxideGeneral Carbon Monoxide InformationCarbon monoxide is a colorless, odorless and tasteless poison gas thatcan be fa

Page 15 - 7. Maintenance

1. Information About Carbon MonoxideCarbon Monoxide PPM Levels(model KN-COP-DP-LS with digital display only)Model KN-COP-DP-LS is equipped with a digi

Page 16

1. Information About Carbon Monoxide• Blocked chimneys or flues, back drafts and changes in air pressure,corroded or disconnected vent pipes, loose or

Page 17

1. Information About Carbon MonoxideBecause carbon monoxide is a cumulative poison, long-term exposuresto low levels may cause symptoms, as well as sh

Page 18 - TEN YEAR LIMITED WARRANTY

Tamper-Resist FeatureThis is a constant 85dB alert to notify consumers the unit has beenunplugged or has come loose from the outlet. THIS FEATURE IS

Comments to this Manuals

No comments