Kidde KN-COPP-3 Brochure Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
"0" NONE
BATTERY IS FULLY CHARGED,
FIRST 5 MINUTES OF OPERATION
ON BACKUP BATTERY
CONNECT TO AC POWER
"0" OR CO
CONCENTRATION
DISPLAYED ONCE EVERY
60 SECONDS, FLASHING
DOT
NONE
BATTERY IS FULLY CHARGED AND
AFTER 5 MINUTES OF OPERATION
ON BACKUP BATTERY
NORMAL BATTERY-ONLY OPERATION.
TO RECHARGE BATTERY, CONNECT TO
AC POWER.
"0" OR CO
CONCENTRATION
ALTERNATING WITH "Lb"
NONE
BATTERY IS PARTIALLY
DISCHARGED, FIRST 5 MINUTES
OF OPERATION ON BACKUP
BATTERY
CONNECT TO AC POWER TO FULLY
RECHARGE BATTERY
"0" OR CO
CONCENTRATION & "Lb"
DISPLAYED ONCE EVERY
60 SECONDS, FLASHING
DOT EVERY SECOND
1 CHIRP EVERY 15
SECONDS
BATTERY IS PARTIALLY
DISCHARGED AFTER 5 MINUTES
OF OPERATION ON BACKUP
BATTERY
FLASHING DOT ONCE
EVERY 60 SECONDS
1 "CHIRP" EVERY 60
SECONDS
OPERATION ON BATTERY BACKUP
AND BATTERY IS FULLY
DISCHARGED.
NONE NONE
BATTERY DISCONNECTED OR
MISSING
CONFIRM BATTERY CONNECTION IS
FULLY SEATED AND ORIENTED
PROPERLY, CONNECT TO AC POWER
TO FULLY CHARGE BATTERY.
CONTACT KIDDE CUSTOMER SERVICE IF
CONDITION CONTINUES
18
If at any time you test the alarm and it does not perform as described, have it replaced immediately.
Part Six Display Readings and What They Mean
DC POWERED IN BATTERY BACKUP OPERATION
Display Shows Alarm Sound Unit Status Unit Condition Recommended Action
2507-7205-00 4/6/05 17:14 Page 20
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23

Comments to this Manuals

No comments