AC Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization Smoke
Alarm with HUSH
TM
Control to temporarily silence nuisance alarms.
Models i12040A and i12080A have a 9-Volt Battery Back Up and the model
i12080A has a battery powered safety light.
Thank you for purchasing this smoke alarm. It is an important part of your family’s
home safety plan. You can trust this product to provide the highest quality safety pro-
tection. We know you expect nothing less when the lives of your family are at stake.
Kidde alarms and accessories CAN ONLY BE interconnected with other Kidde alarms
and accessories as well as specified brands and models of interconnect compatible
alarms. Connection of Kidde products to a non-specified manufacturer’s interconnect
system, or connection with non-specified equipment from another manufacturer into
an existing Kidde system could result in nuisance alarming, failure to alarm, or dam-
age to one or all of the devices in the interconnect system. Refer to the User’s Guide
supplied with each Kidde product for interconnect compatible models, brands, and
devices. Refer to the wiring instructions in section 3 for NFPA initiating device limits.
For models:
i12020A, i12040A, i12080A
Manual P/N 820-1183 Rev.D
1220-7205-00
i12020A
i12040A
i12080A
For your convenience, write down the following information. If you call
our Consumer Hotline, these are the first questions you will be asked.
Smoke Alarm Model Number
(located on back of alarm):
Date Code (located on back of alarm): The
National Fire Protection Association (NFPA)
and the manufacturer recommend replacing
this alarm ten years from the date code.
Date of Purchase:
Where Purchased:
Smoke Alarm User’s Guide
SIGNALING
LISTED
U
L
1220-7205-00(820-1183D-EN).qxd:_ 2010.9.3 7:04 PM Page 1
Page view 0
1 2 ... 17

Summary of Contents

Page 1 - Smoke Alarm User’s Guide

AC Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization SmokeAlarm with HUSHTMControl to temporarily silence nuisance alarms.Models i1

Page 2 - CONTENTS OF THIS MANUAL

Testing: Test by pushing the Test/Hush button on the cover and hold it down for a minimum of 5 seconds. This will soundthe alarm if the electronic ci

Page 3 - FIGURE 2 FIGURE 3

To replace the batteries or the lamp (models i12040A and i12080A only), removethe alarm from the trim ring by rotating the alarm in the direction of t

Page 4 - 2. LOCATIONS TO AVOID

NOTE: WEEKLY TESTING IS REQUIRED! If the Safety Light appears dimduring regular testing, replace both batteries immediately.USE ONLY THE FOLLOWING 9

Page 5 - WIRING REQUIREMENTS

CLEANING YOUR ALARMYOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEARTo clean your alarm, remove it from the mounting bracket as outlined in thebeginni

Page 6

• If the alarm is located outside the bedroom or on a different floor, it may notwake up a sound sleeper.• The use of alcohol or drugs may also impair

Page 7 - MOUNTING INSTRUCTIONS

time getting dressed or picking up valuables.• In leaving, don’t open any inside door without first feeling its surface. If hot, orif you see smoke se

Page 8 - 4. OPERATION AND TESTING

shall be installed as follows: (1) In all sleeping rooms Exception: Smoke alarmsshall not be required in sleeping rooms in existing one- and two-famil

Page 9

TEN YEAR LIMITED WARRANTYKidde warrants to the original purchaser that the enclosed smoke alarm (but not thebattery) will be free from defects in mate

Page 10 - 5. NUISANCE ALARMS

This alarm detects products of combustion using the ionization technique. Itcontains 0.9 microcurie of Americium 241, a radioactive material (see sect

Page 11

FIGURE 1FIGURE 2 FIGURE 3• Locate at least one alarm on every floor level.• Locate an alarm in every sleeping room.• Locate an alarm in every room whe

Page 12

• Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3ft(0.9m) of the highest point (measured horizontally). NFPA 72 states: “S

Page 13 - CLEANING YOUR ALARM

door to a kitchen, the door to a bathroom containing a tub or shower, forcedair supply ducts used for heating or cooling, ceiling or whole house venti

Page 14 - 8. GOOD SAFETY HABITS

nect up to a total of 6 remote signaling devices and/or relay modules.• When mixing models which have battery backup (i12040, i12040A, i12060,i12060A,

Page 15 - 10. NFPA REQUIRED PROTECTION

MOUNTING INSTRUCTIONSCAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE!1. Remove the trim ring from the back of the alarm by holding the trim r

Page 16 - 12. SERVICE AND WARRANTY

TAMPER RESIST LOCKING PIN: To make your smoke alarm tamper resistant, alocking pin has been provided with your alarm. Using this pin will help deterc

Page 17 - TEN YEAR LIMITED WARRANTY

This alarm has a low battery HUSH feature. If the alarm is sounding a low bat-tery warning chirp, you can silence this chirp for approximately 13 hour