Manual P/N 820-1020 Rev. C 06/09
ATTENTION: Please take a few minutes to thoroughly read this
user’s guide, which should be saved for future reference and
passed on to any subsequent owner.
Smoke Alarm
User’s Guide
Pi2010CA
Dual Sensor
Pi2010CA
120 V AC Direct Wire
S
INGLE AND/OR MULTIPLE
S
TATION SMOKE ALARM
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - User’s Guide

Manual P/N 820-1020 Rev. C 06/09ATTENTION: Please take a few minutes to thoroughly read thisuser’s guide, which should be saved for future reference a

Page 2 - Introduction

Installation9FUSE OR CIRCUIT BREAKERREDBLACKLIVENEUTRALWHITEBLACKWHITEREDCONNECTORCONNECTORFirstAlarmAdditionalAlarmKiddeRelay ModuleSM120XAdditionalA

Page 3

Installation10MountingCAUTION: This unit is sealed. The cover is not removable!• Remove the mounting plate from the back of the alarm byholding the mo

Page 4

Installation11• Pull the AC Quick-Connect wire harness through thecenter hole in the mounting bracket and secure thebracket, making sure that the moun

Page 5

12InstallationBatteryThis unit will not function without a properly installedbattery. When installing a battery, press the batteryreminder tab down in

Page 6

Operation13Hush®Control FeatureSmoke alarms are designed to minimize nuisance alarms.Cigarette smoke will not normally set off the alarm, unlessthe sm

Page 7

Operation14Alarm Tamper-Resist FeatureThis alarm has a tamper-resist feature. This feature willhelp deter children or others from removing the alarmfr

Page 8

15LED IndicatorsThis smoke alarm is equipped with red and green LEDindicators. The red LED is located under the test button andhas several modes of op

Page 9

When Units Are InterconnectedOnly the red LED of the alarm “which senses the smoke” or“is being tested” (the originating unit) will flash rapidly. All

Page 10 - Installation

Maintenance17Alarm RemovalIf the smoke alarm tamper resist feature has been activated, referto the alarm tamper-resist feature section for removal ins

Page 11

18MaintenanceWARNING! Use only the batteries specified. Use of different batteries than therecommended ones, may have a detrimental effect on the smok

Page 12

Introduction . . . . . . . . . . . . . . . . . . . . . . . . 1Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 2–12Operation . . . . .

Page 13 - Operation

19Fire SafetyLimitations of Smoke AlarmsWARNING: Please read carefully and thoroughly.• NFPA 72 states: Fire-warning equipment for residentialoccupanc

Page 14

20Fire SafetyGood Safety HabitsDevelop and practice a plan of escape!Make a floor plan indicating all doors and windows and atleast two (2) escape rou

Page 15

21Fire Safety• Stay close to the floor if the air is smoky. Breathe shallowlythrough a cloth, wet if possible.• Once outside, go to your selected meet

Page 16

Fire Safety22Additional RecommendationsThe National Fire Protection Association’s Standard 72provides the following information:Smoke Detection. Where

Page 17 - When Units Are Interconnected

Warranty23If after reviewing this manual you feel that your smoke alarmis defective in any way, do not tamper with the unit. In manycases, the quickes

Page 18 - Maintenance

This unit is suitable as a single station and/or multiplestation alarm (interconnects with up to 24 devices), andhas a ten-year limited warranty.IMPOR

Page 19

Recommended Locations• Locate the first alarm in the immediate area of the sleepingrooms. Try to monitor the exit path, as the sleeping rooms areusual

Page 20 - Fire Safety

• In homes that are not well insulated, extreme heat or coldcan be transferred from the outside to the inside throughpoorly insulated walls and roof.

Page 21

• Install Smoke Alarms on tray-shaped ceilings (cofferedceilings) on the highest portion of the ceiling or on thesloped portion of the ceiling within

Page 22

Installation6IMAGE 2AIMAGE 2CIMAGE 2BHORIZONTAL DISTANCE FROM PEAKCEILING10 cm (4”)MINIMUM10 cm (4”)MINIMUM30.5 cm (12”)MAXIMUMSIDE WALLBESTPLACEMENTA

Page 23

Mobile HomesModern mobile homes have been designed and built to be energyefficient. Install smoke alarms as recommended in RecommendedLocations and Im

Page 24 - Warranty

• WARNING: The alarm should not be operated on power derivedfrom a square wave, modified square wave or modified sine waveinverter. These power source