Operating Instructions
16
CO Alarm Response Time
Never restart the source of a CO problem until it has
been fixed. NEVER IGNORE THE ALARM!
The CO sensor meets the alarm response time requirements of UL
standard 2034. Standard alarm times are as follows:
At 70 PPM, the unit must alarm within 60-240 minutes.
At 150 PPM, the unit must alarm within 10-50 minutes.
At 400 PPM, the unit must alarm within 4-15 minutes.
This carbon monoxide alarm is designed to detect
carbon monoxide gas from ANY source of combus-
tion. It is NOT designed to detect any other gas.
Fire Departments, most utility companies and HVAC con-
tractors will perform CO inspections, some may charge for
this service. It’s advisable to inquire about any applicable
fees prior to having the service performed. Kidde will not
pay for, or reimburse, the owner or user of this product, for
any repair or dispatch calls related to the alarm sounding.
IF THE TAMPER RESIST FEATURE HAS BEEN ACTIVATED,
REFER TO TAMPER RESIST FEATURE DESCRIPTION ON
PAGE 17 FOR REMOVAL INSTRUCTIONS
.
Remove the alarm from the mounting bracket by rotating
the alarm in the direction of the “OFF” arrow on the cover.
Alarm Removal
NOTE: Before activating the battery carrier tamper resist feature,
make sure a fresh battery is installed in the unit and that the battery
carrier is properly closed. If the battery carrier tamper resist feature
is activated while the battery carrier is open, the battery carrier will
not close and the unit will be inoperable.
To deactivate the battery carrier tamper resist, in order to change
the smoke alarm battery, remove the unit from the trim plate (see
Smoke Alarm Tamper Resist Feature if activated), and locate the
small cut-out in the middle of the product label. Using a screwdriver,
or similar tool, slide the switch towards the bottom of the product
label. The battery carrier can now be opened and the battery
changed.