A.C. Wire-in Single and/or Multiple Station (up to 24 Devices) IonizationSmoke Alarm with 9 Volt Battery Back Up and HUSHTMControl to temporar-ily sil
LED INDICATORS: This smoke alarm is equipped with red and green LED indica-tors. The green LED (when illuminated) indicates the presence of AC power.T
5. NUISANCE ALARMSSmoke alarms are designed to minimize nuisance alarms. Cigarette smoke willnot normally set off the alarm, unless the smoke is blow
This smoke alarm uses a 9V carbon zinc battery (alkaline and lithium batteriesmay also be used). A fresh battery should last for one year under normal
CLEANING YOUR ALARMYOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEARTo clean your alarm, remove it from the mounting bracket as outlined in thebeginni
• Smoke alarms cannot provide an alarm if smoke does not reach the alarm.Therefore, smoke alarms may not sense fires starting in chimneys, walls, onro
WHAT TO DO WHEN THE ALARM SOUNDS• Alert small children in the home. • Leave immediately by your escape plan. Every second counts, so don’t wastetime
10. NFPA REQUIRED PROTECTIONThe National Fire Protection Association’s Standard 72 provides the followinginformation:Smoke Detection – Where required
12. SERVICE AND WARRANTYIf after reviewing this manual you feel that your smoke alarm is defective in anyway, do not tamper with the unit. Return it
TEN YEAR LIMITED WARRANTYKidde warrants to the original purchaser that the enclosed smoke alarm (but not thebattery) will be free from defects in mate
This alarm detects products of combustion using the ionization technique. Itcontains 0.9 microcurie of Americium 241, a radioactive material (see Sect
FIGURE 1FIGURE 2 FIGURE 3• Locate an alarm in every room where someone sleeps with the door closed.The closed door may prevent an alarm not located in
MOBILE HOME INSTALLATIONModern mobile homes have been designed and built to be energy efficient.Install smoke alarms as recommended above (refer to RE
3. INSTALLATION INSTRUCTIONSWIRING REQUIREMENTS• This smoke alarm should be installed on a U.L. listed or recognized junctionbox. All connections shou
• For more information about compatible interconnect units and their function-ality in an interconnect system, visit our web site at: www.Kidde.com• T
OF WALL MOUNTED SMOKE ALARMS WILL DECREASE OPERATIONALEFFECTIVENESS.1. Remove the trim ring from the back of the alarm by holding the trim ring andtwi
CAUTION: Due to the loudness (85 decibels) of the alarm, always standan arms length away from the unit when testing.8. Turn on the AC power. The gree
The tamper resist feature is now active and the battery carrier can not beopened until the tamper resist feature is deactivated.NOTE: Before activatin