A.C. Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization
Smoke Alarm with 9 Volt Battery Back Up and SMART HUSH
TM
Control to
temporarily silence nuisance alarms.
Thank you for purchasing this smoke alarm. It is an important part of your family’s
home safety plan. Y
ou can trust this product to provide the highest quality safety
protection. We know you expect nothing less when the lives of your family are at
stake. Kidde alarms and accessories CAN ONLY BE interconnected with other Kidde
alarms and accessories as well as specified brands and models of interconnect com-
patible alarms. Connection of Kidde products to a non-specified manufacturer’s
interconnect system, or connection with non-specified equipment from another
manufacturer into an existing Kidde system could result in nuisance alarming, fail-
ure to alarm, or damage to one or all of the devices in the interconnect system.
Refer to the User’s Guide supplied with each Kidde product for interconnect com-
patible models, brands, and devices. Refer to the wiring instructions in section 3 for
NFPA initiating device limits.
For model: i12060
Manual P/N 820-0394-EN Rev. D
i12060
For your convenience, write down the following information. If you call
our Consumer Hotline, these are the first questions you will be asked.
Smoke Alarm Model Number
(located on back of alarm):
Date Code (located on back of alarm): The
National Fire Protection Association (NFPA)
and the manufacturer recommend replacing
this alarm ten years from the date code.
Date of Purchase:
Where Purchased:
Smoke Alarm User’s Guide
Page view 0
1 2 ... 17

Summary of Contents

Page 1 - Smoke Alarm User’s Guide

A.C. Wire-in Single and/or Multiple Station (up to 24 Devices) IonizationSmoke Alarm with 9 Volt Battery Back Up and SMART HUSHTMControl totemporarily

Page 2 - CONTENTS OF THIS MANUAL

The red LED has four modes of operation:Standby Condition: The red LED will flash every 30-40 seconds to indicate that the smoke alarm is operating pr

Page 3 - FIGURE 2 FIGURE 3

5. NUISANCE ALARMSSmoke alarms are designed to minimize nuisance alarms. Cigarette smoke willnot normally set off the alarm, unless the smoke is blow

Page 4 - 2. LOCATIONS TO AVOID

This smoke alarm uses a 9V carbon zinc battery (alkaline and lithium batteriesmay also be used). A fresh battery should last for one year under normal

Page 5 - WIRING REQUIREMENTS

vacuuming through the openings around the perimeter of the alarm. The out-side of the alarm can be wiped with a damp cloth. After cleaning, reinstall

Page 6 - MOUNTING INSTRUCTIONS

• The use of alcohol or drugs may also impair one’s ability to hear the smokealarm. For maximum protection, a smoke alarm should be installed in each

Page 7

• In leaving, don’t open any inside door without first feeling its surface. If hot,or if you see smoke seeping through cracks, don’t open that door!

Page 8 - TAMPER RESIST FEATURES

Smoke Detection – Are More Smoke Alarms Desirable? The required number ofsmoke alarms might not provide reliable early warning protection for those a

Page 9 - 4. OPERATION AND TESTING

FIVE YEAR LIMITED WARRANTYKIDDE Safety warrants to the original purchaser that the enclosed smoke alarm (but notthe battery) will be free from defects

Page 10

This alarm detects products of combustion using the ionization technique. Itcontains 0.9 microcurie of Americium 241, a radioactive material (see Sect

Page 11 - 6. MAINTENANCE

FIGURE 1FIGURE 2 FIGURE 3• Locate an alarm in every room where someone sleeps with the door closed.The closed door may prevent an alarm not located in

Page 12 - CLEANING YOUR ALARM

MOBILE HOME INSTALLATIONModern mobile homes have been designed and built to be energy efficient.Install smoke alarms as recommended above (refer to RE

Page 13

3. INSTALLATION INSTRUCTIONSWIRING REQUIREMENTS• This smoke alarm should be installed on a U.L. listed or recognized junctionbox. All connections shou

Page 14 - 8. GOOD SAFETY HABITS

• The maximum wire run distance between the first and last unit in an intercon-nected system is 1000 feet.• Figure 4 illustrates interconnection wirin

Page 15 - 10. NFPA REQUIRED PROTECTION

1. Remove the trim ring from the back of the alarm by holding the trim ring andtwisting the alarm counter-clockwise.2. After selecting the proper smok

Page 16 - 12. SERVICE AND WARRANTY

8. Turn on the AC power. The green Power On Indicator should be lit when thealarm is operating from AC power. Confirm unit operation by pressing theTe

Page 17 - FIVE YEAR LIMITED WARRANTY

NOTE: Before activating the battery carrier tamper resistfeature, make sure a fresh battery is installed in the unitand that the battery carrier is pr